This is the latest recevied telemetry packets stored in our database for station/object DL8GAK-9. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | Celsius* | Rel_Hum* | Atm_Press* | Value4* | Value5* |
|---|---|---|---|---|---|
| 1795039325 | 18.4 C | 58 % | 1003.5 hPa | 0 | 0 |
| 1795039296 | 18.4 C | 58 % | 1004.88 hPa | 0 | 0 |
| 1795039261 | 18 C | 58 % | 1002.38 hPa | 0 | 0 |
| 1795039238 | 18 C | 58 % | 1004.38 hPa | 0 | 0 |
| 1795039221 | 17.6 C | 58.65 % | 1004.63 hPa | 0 | 0 |
| 1795039204 | 17.6 C | 58.65 % | 1004.13 hPa | 0 | 0 |
| 1795039187 | 17.6 C | 58.65 % | 1004.5 hPa | 0 | 0 |
| 1795039157 | 17.1 C | 59.3 % | 1004.13 hPa | 0 | 0 |
| 1795039140 | 17.1 C | 59.3 % | 1003.88 hPa | 0 | 0 |
| 1795039123 | 17.1 C | 59.3 % | 1005.75 hPa | 0 | 0 |
| 1795039061 | 16.7 C | 60.03 % | 1006 hPa | 0 | 0 |
| 1795039044 | 16.1 C | 60.45 % | 1008.38 hPa | 0 | 0 |
| 1795039027 | 16.1 C | 60.45 % | 1006.75 hPa | 0 | 0 |
| 1795038888 | 15 C | 61.23 % | 1002.88 hPa | 0 | 0 |
| 1795038871 | 15 C | 61.23 % | 1003.88 hPa | 0 | 0 |
| 1795038854 | 14.5 C | 61.65 % | 1010.38 hPa | 0 | 0 |
| 1795038837 | 14.5 C | 61.65 % | 1008.88 hPa | 0 | 0 |
| 1795038820 | 14.5 C | 61.65 % | 1005.38 hPa | 0 | 0 |
| 1795038803 | 13.9 C | 61.75 % | 1008.63 hPa | 0 | 0 |
| 1795038786 | 13.9 C | 61.75 % | 1007.13 hPa | 0 | 0 |
| 1795038769 | 13.9 C | 61.75 % | 1006.13 hPa | 0 | 0 |
| 1795038731 | 13.2 C | 62.26 % | 1005.75 hPa | 0 | 0 |
| 1795038714 | 13.2 C | 62.26 % | 1005.5 hPa | 0 | 0 |
| 1795038687 | 13.2 C | 62.26 % | 1004 hPa | 0 | 0 |
| 1795038670 | 12.7 C | 62.45 % | 1004.75 hPa | 0 | 0 |
*Used Equation Coefficients:
Celsius: 0, 0.1, -50
Rel_Hum: 0, 0.01, 0
Atm_Press: 0, 0.125, 0
Value4: 0, 1, 0
Value5: 0, 1, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)