This is the latest recevied telemetry packets stored in our database for station/object SQ9PQL-00. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | TX* | RX* | Digi* | V_Bat* | V_Ext* |
|---|---|---|---|---|---|
| 1795120713 | 978 Count | 366 Count | 318 Count | 0 VDC | 0 VDC |
| 1795119809 | 976 Count | 365 Count | 317 Count | 0 VDC | 0 VDC |
| 1795118905 | 974 Count | 364 Count | 316 Count | 0 VDC | 0 VDC |
| 1795118001 | 972 Count | 363 Count | 315 Count | 0 VDC | 0 VDC |
| 1795117098 | 970 Count | 362 Count | 314 Count | 0 VDC | 0 VDC |
| 1795116194 | 968 Count | 361 Count | 313 Count | 0 VDC | 0 VDC |
| 1795115290 | 966 Count | 360 Count | 312 Count | 0 VDC | 0 VDC |
| 1795114386 | 964 Count | 359 Count | 311 Count | 0 VDC | 0 VDC |
| 1795113483 | 962 Count | 358 Count | 310 Count | 0 VDC | 0 VDC |
| 1795112579 | 960 Count | 357 Count | 309 Count | 0 VDC | 0 VDC |
| 1795111674 | 958 Count | 356 Count | 308 Count | 0 VDC | 0 VDC |
| 1795110770 | 956 Count | 355 Count | 307 Count | 0 VDC | 0 VDC |
| 1795109867 | 954 Count | 354 Count | 306 Count | 0 VDC | 0 VDC |
| 1795108963 | 952 Count | 353 Count | 305 Count | 0 VDC | 0 VDC |
| 1795108059 | 950 Count | 351 Count | 304 Count | 0 VDC | 0 VDC |
| 1795107155 | 948 Count | 350 Count | 303 Count | 0 VDC | 0 VDC |
| 1795106252 | 946 Count | 349 Count | 302 Count | 0 VDC | 0 VDC |
| 1795105348 | 944 Count | 347 Count | 301 Count | 0 VDC | 0 VDC |
| 1795104444 | 942 Count | 345 Count | 300 Count | 0 VDC | 0 VDC |
| 1795103540 | 940 Count | 344 Count | 299 Count | 0 VDC | 0 VDC |
*Used Equation Coefficients:
TX: 0, 1, 0
RX: 0, 1, 0
Digi: 0, 1, 0
V_Bat: 0, 0.01, 0
V_Ext: 0, 0.02, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)